Three Phase Over Current & Earth fault Numeric Relay Testing System is a useful product for Electrical Power System Laboratories. The main purpose of protection relay is to detect and identify faults and interrupts power to the equipment to avoid the entire network to fail or cause more damages to personnel or equipment. 
An Over Current Relay operates when the load current exceeds a preset value, whereas the function of Earth Fault Relay is to protect any system from earth fault. includes inbuilt Microcontroller based Three Phase Over Current and Earth Fault Numerical Relay with facilities to select various characteristic curves at different Time Multiplier Settings (TMS) and Current Settings. 
The setting and selection of characteristic curves are carried out by a soft touch keypad provided on the front panel of the Numeric Relay. There is a large font LCD to display all necessary parameters in a single frame. 

Product Description

Technical Specifications

Features:
Four element (Three Phase + Earth Fault) Non Directional Over Current IDMT/DMT Numeric Relay
Numeric Relay provides with Curve’s Selection Facility: Normal Inverse 1(C1), Normal Inverse 2(C2), Very Inverse (C3), Extremely Inverse (C4), Long time Inverse (C5) and define Time (C6)
Compatible for Internal calculation of zero sequence current (3Io) under earth fault
Provided with CT Secondary Selection Facility (1A or 5A)
Large Font LCD for input current and tripping time display
Provided with Current Injection Source
Microcontroller based Numeric Relays Demonstration
Designed by considering all the safety measures
Diagrammatic Representations for the ease of connections
Scope of Learning:
Study and verify Operating Characteristics of Three Phase Over
Current and Earth Fault Numeric Relay with different Time
Multiplier Settings (TMS) and Current Setting
Study and use of Time Setting Multiplier (TMS) in Numeric
Relay
Study about working and connection of Three Phase Over
Current and Earth Fault Numeric Relay in Transmission Line

Technical Specifications:

  •    Mains Supply         :     Three Phase, 415V ±10%, 50Hz
  •    Auxiliary Supply     :     230V ±10%, 50Hz

Display Measurements

  •     Current Input         :     >100mA
  •     Time Accuracy       :     1 Second

Over Current and Earth Fault Relay

  •     Input Current            :     Suitable for CT Secondary 5A (or) 1A
  •     Pick up                     :     Within 1.1 times of set value
  •     Reset value              :     90% to 95% of pickup
  •     Auxiliary Supply        :     18-250V AC/DC
  •     MCB (TPN)               :     10A
  •     Dimensions (mm)     :     W 560 x D 350 x H 420
  •     Weight                      :     33kg (approximate)
     

Insif Products

Our Related Product

Lab Plasticware
Biology
Chemistry
Civil & Survey
Pharmacy Lab Equipments
Spaq Labs has regular exports to the following countries: India, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma/ Myanmar, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia, Comoros, Congo, Congo, Costa Rica, Cote d'Ivoire/Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Dominican Republic, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Finland, France, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakstan, Kenya (Nairobi), Kiribati, Korea, North, Korea, South, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mauritius, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Portugal, Qatar, Romania, Russia, Rwanda (Kigali), Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sri Lanka, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Tanzania, Thailand, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, United Arab Emirates (Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe